Home > Knowledge

Maintenance and troubleshooting of 2.5 Ton battery locomotive

2021-07-27
As a important transportation vehicle in mining, its very important for us to do the daily maintenance and knowing some troubleshooting of the 2.5ton battery locomotive(model type is CTY2.5/6,7,9GB)
Today i will list some important matter of maintenance.

(1) Check whether the lever and pin of the brake system are in good condition, whether they are flexible in action, and fill in oil. To
   (2) Check the brake shoe wear and replace the brake shoe with excessive wear; check the gap between the brake shoe and the wheel tread, and adjust it in time if it exceeds the specified limit; remove the mud on the adjusting brake shoe screw and brake shoe. To
  (3) Check whether the wheel is cracked, whether the wheel tyre is loose, and whether the wheel tread is worn. To
  (4) Check the transmission gear and gear cover for looseness and wear. To
  (5) Check the frame spring for cracks and failures, remove the dirt on the spring, and inject oil between the hinge point and the balance beam. To
  (6) Check whether the car body and all bolt pins and cotter pins are complete, whether the bolts are tight, and whether the pin shaft and the cotter pin are well connected. Especially the device that hangs the traction motor should be checked carefully. To
  (7) Check the connecting device for damage and wear exceeding the limit. To
  (8) Check whether the various parts of the sand removal system are complete, well connected, whether the sand pipe is blocked, whether it is aligned with the center of the track, and whether the distance between the wheel and the track meets the requirements. To
  (9) Check whether the spring pressure of the electrical receiver is sufficient, whether the sliding plate is broken and worn out of limit, whether the frames, bolts and pins are complete and expanded. To
  (10) Check whether the resistor is broken, whether the wiring terminals are loose, and clean the dust. To
  (11) Test whether the mechanical locking device of the controller is reliable, and whether the terminals 0 are loose; check the contacts of the controller, especially the frequently used contacts for burnout. To
  (12) Check the condition of the traction motor, the bearing bush and the fuel tank immediately after the electric locomotive is out of service. Whether the temperature of the motor exceeds (75 ℃) and whether the bearing bush temperature exceeds the limit (65 ℃), remove the dust in the fuel tank, and regularly fill and change the oil. To
  (13) Whether the lighting is in good condition and the brightness is sufficient, and the fuse should meet the requirements.

Above are some important matters of 2.5ton battery locomotive Maintenance and troubleshooting.